Extinguishing system with sprinkler / hydrant pumping station
Extinguishing system with sprinkler / hydrant pumping station
Sebino Fire and Security performs a quarterly inspection which is carried out in accordance with UNI EN 12845 standards, providing useful recommendations in terms of the design, installation and maintenance of fixed sprinkler fire prevention systems in buildings and industrial sites, and special requirements for sprinkler systems.
UNI 45 / UNI 70 Hydrants
With reference to UNI EN 10779 standard – point 10.4 relating to the periodic maintenance of systems and hydrant networks, Sebino Fire and Security commits to perform a series of specific tests every six months.
Fire extinguishers
UNI 9994 standard refers to the criteria for surveillance, control, inspection and testing of fire extinguishers, in order to guarantee their operational efficiency, and sets four maintenance phases.
Maintenance of smoke and heat exhaust system
With reference to UNI 9494 standard on smoke and natural and forced heat evacuation systems, Sebino Fire and Security, as maintenance manager, is responsible for a series of tests to be performed every six months.
Maintenance of smoke and heat exhaust system
It covers testing the status and correct operation of the various mechanisms and fire doors and gates operation according to UNI 11473 standards. A specific range of six-monthly operations is also included.
Maintenance of flood system with automatic control via temperature detectors and manual foam system
The quarterly / six-monthly inspection suggested by Sebino is performed in accordance with UNI CEN TS 14816 – 13565 standards and involves the performance of specific operations.
Maintenance of automatic CO2 system
The six-monthly inspection suggested by Sebino Fire and Security is based on UNI 11224 and 11280 Standards referring to initial control and maintenance procedures (surveillance, control and inspection) of fire extinguishing gas systems.
Maintenance of the powder system
The six-monthly inspection suggested by Sebino Fire and Security involves the fulfillment of specific tasks according to UNI EN 12416 Standard referring to requirements and recommendations on design, construction and maintenance of powder systems.
Maintenance of water curtain system
Sebino Fire and Security suggests a quarterly / six-monthly inspection to be carried out in accordance with UNI CEN TS 14816 standards, with all requirements and recommendations on design, installation and maintenance of fixed water flood systems for indoor or outdoor installation of both civil and industrial buildings.
Maintenance of automatic foam system
The suggested quarterly / six-monthly inspection is carried out in accordance with UNI EN 13565 standards by applying specific procedures.
Maintenance of gas extinguishing system
Six-monthly inspection in compliance with the periodic control procedures prescribed by UNI 11224 and 11280 standards. The indications deal with initial control, surveillance and periodic control, maintenance and general testing procedures for automatic fire detection systems and gas fire extinguishing systems.